7 - 6 7 - 6

MELSEC-Q

7 DATA COMMUNICATIONS USING BIDIRECTIONAL PROTOCOL

(2) Arrangement of receive data

The following example illustrates the arrangement of data received from the

external device when it is stored in the receive area.

1) The receive message is stored to the Q series C24 buffer memory (receive

data storage area).

2) The data is stored to the receive data storage area in low address (L) (H),

next address (L) (H) order.

If the received data is "ABCDEFG123", it will be stored as shown below (for

the CH1 side):

ENQ (0005

H

)

A

B

C

D

E

F

G

1

2

3

L

H

L

H

05

H

00

H

41

H

46

H

44

H

42

H

43

H

32

H

45

H

31

H

47

H

33

H

47

H

02

H

Sum

check

code

5

(00

H

)

(05

H

)

B

(42

H

)

D

(44

H

)

F

(46

H

)

1

(31

H

)

3

(33

H

)

A

(41

H

)

C

(43

H

)

E

(45

H

)

G

(47

H

)

2

(32

H

)

Receive
data count
storage area

Receive
data storage
area

Receive area

(buffer memory)

Q series C24

External device

Transmission data (response message)

ACK

06

H

(Normal completion)

Data

length

Receive data (response message)

When the data length unit is in bytes, 00

H

is stored in the higher byte of the

last data storage position in the receive area when the data length of the

message is an even byte.

(3) Contents of receive data

The contents of receive data, including the receive data as indicated in

Section 7.2.2, are explained below.

(a) Control codes

The types of control codes are shown in the table below.

Signal

name

Code

(hexadecimal)

Contents

Application

ENQ

05

H

Enquiry

Code for starting data transmission.

ACK

06

H

Acknowledge

Response code to the opposite side when data was

received normally.

NAK

15

H

Negative

Acknowledge

Response code to the opposite side when data could

not be received normally. (Error code is sent

immediately after the response code.)

1) For data communication from the external device to the Q series C24

the Q series C24 checks and processes the control code received.

It cannot be read from the sequence program.

2) For data communication from the Q series C24 to the external device

The control code to be transmitted is added by the Q series C24.

Advertising