(2) Communication error clear request for CH and to turn LED off on

Monitor/test others screen

This is used to turn off the CH LED of the Q series C24 and to initialize (clear)

the communication error information.

The CH LED on status and communication error information can be confirmed

on the Monitor/test others screen.

[Operation procedure]

1) Display the "Monitor/test others" screen.

2) Select any of "Request 1 to 3" for "Communication error clear request for CH

and to turn LED off".

Setting range

Target of LED off/communication error information initialization

Request 1

SIO, PRO., P/S, C/N, NAK, ERR. LED ( 1)

Request 2

SD WAIT, ACK., NEU. LED

Request 3

All of Requests 1 and 2

1 The ERR. LED is turned off. (However, it is not turned off if an error has

occurred on either the CH1 or CH2 side.)