Melsec-q, 1 overview, Run init. open sd err. com.err rd 10base-t 10base – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 28

Advertising
background image

1 - 3 1 - 3

MELSEC-Q

1 OVERVIEW

Q25HCPU

MODE

RUN

ERR.

USER

BAT.

BOOT

RS-232

USB

MITSUBISHI

MELSEC

POWER

PULL

QJ71E71

RUN

INIT.

OPEN

SD

ERR.

COM.ERR

RD

10BASE-T

+

12V

12G

10BASE

QJ71C24

CH1.

CH2.

RS-232

CH1.

CH.2

SDA

SG

SDB

RS-422
/485

RDA

RDB

(FG)

(FG)

1

2

5

7

3

4

6

Q25HCPU

MODE

RUN

ERR.

USER

BAT.

BOOT

RS-232

USB

MITSUBISHI

MELSEC

POWER

PULL

QJ71E71

RUN

INIT.

OPEN

SD

ERR.

COM.ERR

RD

10BASE-T

10BASE

QJ71C24

CH1.

CH2.

RS-232

CH1.

CH.2

SDA

SG

SDB

RS-422
/485

RDA

RDB

(FG)

(FG)

1

2

5

7

3

4

6

Q25HCPU

MODE

RUN

ERR.

USER

BAT.

BOOT

RS-232

USB

MITSUBISHI

MELSEC

POWER

PULL

QJ71E71

RUN

INIT.

OPEN

SD

ERR.

COM.ERR

RD

10BASE-T

+

12V

12G

10BASE

QJ71C24

CH1.

CH2.

RS-232

CH1.

CH.2

SDA

SG

SDB

RS-422
/485

RDA

RDB

(FG)

(FG)

1

2

5

7

3

4

6

Command

Command request data

MELSECNET/H

(MELSECNET/H mode)

In the MELSECNET/10 mode, other stations (including the A/QnA series PLC

CPUs) can be accessed during data link operation.

The MC protocol is equivalent to the communication function using a dedicated

protocol that is supported by the A/QnA series computer link module/serial

communication modules.

(2) Data communication using the non procedure protocol

(Details are explained in Chapter 6 and the User's Manual (Application).)

(a) Data can be transferred in any message formats that conform to the

specifications of external devices (measuring devices, PCs, etc.).

(b) Fixed or variable length messages can be received in accordance with the

external device specifications.

• How to receive the variable length data

The external device sends data by adding at the end of the message the

end-code data (CR+LF or any one-byte data) that is set for the Q series C24.

• How to receive the fixed length data

The external device sends the amount of data equivalent to the size of the

end data that is set for the Q series C24.

End

code

Reception data

(When receiving variable length data)

QJ71E71

RUN

INIT.

OPEN

SD

ERR.
COM.ERR

RD

10BASE-T

+12 V

12G

10BASE

RS-232

MODE

RUN

ERR.

USER

BAT.

BOOT

CH.2

SDA

SG

SDB

(FG)

RDA

(FG)

RDB

RS -422
/485

CH1.

CH2.

CH1.

2

1

3

4

5

6

7

RS-232

USB

Q25HCPU

POWER

MELSEC

PULL

MITSUBISHI

QJ71C24

(c) ASCII code data can be used for communication using the ASCII-BIN

conversion function.

ASCII-BIN

conversion

Binary

data

QJ71C24

Binary

data

ASCII

data

QJ71E71

RUN

INIT.

OPEN

SD

ERR.
COM.ERR

RD

10BASE-T

+12V

12G

10BASE

RS-232

MODE

RUN

ERR.

USER

BAT.

BOOT

CH.2

SDA

SG

SDB

(FG)

RDA

(FG)

RDB

RS -422
/485

CH1.

CH2.

CH1.

2

1

3

4

5

6

7

RS-232

USB

Q25HCPU

POWER

MELSEC

PULL

MITSUBISHI

QJ71C24

Advertising
This manual is related to the following products: