2 rs-232 interface specification, 1 rs-232 connector specifications, Melsec-q – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 53

Advertising
background image

3 - 3 3 - 3

MELSEC-Q

3 SPECIFICATIONS

3.2 RS-232 Interface Specification

The following shows the RS-232 interface specifications.

3.2.1 RS-232 connector specifications

The following shows the specifications of the RS-232 connector that connects the Q

series C24 to an external device.

Carrier detect

Receive data

Send data

Data terminal ready

Signal ground

Request to send

Clear to send

CD

RD(RXD)

SD(TXD)

DTR(ER)

SG

DSR(DR)

RS(RTS)

CS(CTS)

RI(CI)

Pin number

Signal name

Signal direction

External
device

1

2

3

4

5

6

7

8

9

C24

9

1

2

3

4

5

6

7

8

Signal

abbreviation

Call Indicate

Dataset ready

(1) The control signals are described below. (The pin numbers of the connector are

enclosed in parentheses.)

1) CD signal (1)

• The Q series C24 operates according to the setting CD terminal check (see

Section 8.4.5) of the Q series C24.

CD terminal check enabled

CD terminal check disabled

Full-duplex

communication

• The Q series C24 performs send and receive

processing when the CD signal (receive

carrier detection) is ON.

• If the CD signal is turned off during data

communication, the Q series C24 initializes

the transmission sequence.

• The Q series C24 performs send and receive

processing regardless of the ON/OFF status

of the CD signal.

• Data communications is possible with an

external device that cannot turn the CD

signal ON/OFF.

Half-duplex

communication

See Chapter 8 of User's Manual (Application)

Setting impossible.

2) RD signal

This is a signal to receive data.

3) SD signal

This is a signal to send data.