Melsec-q, 3 specifications – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 70

Advertising
background image

3 - 20 3 - 20

MELSEC-Q

3 SPECIFICATIONS

Address

Decimal (Hex)

Applicable

protocol

CH1

CH2

Application

Name

Initial

value

MC Non

Bi

Registration

allowed/not

allowed

Reference

section

Switching mode no. designation (0001

H

to 0007

H

, 00FF

H

)

0001

H

: MC protocol (format 1)

0005

H

: MC protocol (format 5)

0002

H

: MC protocol (format 2)

0006

H

: Non procedure protocol

0003

H

: MC protocol (format 3)

0007

H

: Bidirectional protocol

144

(90

H

)

304

(130

H

)

0004

H

: MC protocol (format 4)

00FF

H

: GX Developer

connection

Transmission specifications after switching designation

Designates transmission specifications (below) after switching

when b15 of this area is 1 (ON).

Operation setting (b0)

0: Independent

1: Link

Data bit (b1)

0: 7 bit

1: 8 bit

Parity bit (b2)

0: No

1: Yes

Odd/even parity (b3)

0: Odd

1: Even

Stop bit (b4)

0: 1 bit

1: 2 bit

Sum check code (b5)

0: No

1: Yes

Write during RUN (b6)

0: Prohibited

1: Allowed

Setting modification (b7)

0: Prohibited

1: Allowed

Communication rate (b8 to b11)

50 bps to 230400 bps

For system (b12 to b14)

All 0

145

(91

H

)

305

(131

H

)

For designation of

mode switching

Transmission specifications after switching (b15) designation

0: Match settings in GX Developer

1: Match settings in this area

0

RW

Not allowed

Section

4.5.2

Chapter 15

of User's

Manual

(Application)

146

(92

H

)

306

(132

H

)

Signal setting

(

1)

RS and DTR signal status designation

0: Off 1: On

RS signal (b0)

DTR signal (b2)

For system (b1), (b3) to (b15)

0005

H

RW

Allowed

Section 3.2.1

DTR/DSR(ER/DR), DC control designation

147

(93

H

)

307

(133

H

)

• Transmission control (b0)

0: DTR/DSR control 1: DC code control

• DC1/DC3 control (b8)

0: No control 1: Controlled

• DC2/DC4 control (b9)

0: No control 1: Controlled

0

DC1/DC3(Xon/Xoff) code designation

148

(94

H

)

308

(134

H

)

• DC1 code (b0 to b7)

00

H

to FF

H

: DC1 code

• DC3 code (b8 to b15)

00

H

to FF

H

: DC3 code

1311

H

DC2/DC4 code designation

149

(95

H

)

309

(135

H

)

For designation of

transmission

control

• DC2 code (b0 to b7)

00

H

to FF

H

: DC2 code

• DC4 code (b8 to b15)

00

H

to FF

H

: DC4 code

1412

H

RW

Section

8.4.5

Chapter 7

of User's

Manual

(Application)

150

(96

H

)

310

(136

H

)

Word/byte units designation

0: Word units 1: Byte units

0

Chapters 6

Chapter 7

Section

8.4.5

151

(97

H

)

311

(137

H

)

For designation

of communica-

tion control

CD terminal check designation (for RS-232)

0: Check 1: No check

1

RW

Allowed

Section

3.2.1

Section

8.4.5

Advertising