Melsec-q, 3 specifications – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 80

Advertising
background image

3 - 30 3 - 30

MELSEC-Q

3 SPECIFICATIONS

Address

Decimal (Hex)

Applicable

protocol

CH1

CH2

Application

Name

Initial

value

MC Non

Bi

Registration

allowed/not

allowed

Reference

section

8944 (22F0

H

)

Callback permit accumulated count

0 or more : Accumulated count

8945 (22F1

H

)

Callback denial accumulated count

0 or more : Accumulated count

8946 (22F2

H

)

Auto (callback) connection permit accumulated count

0 or more : Accumulated count

8947 (22F3

H

)

Auto (callback) connection denial accumulated count

0 or more : Accumulated count

8948 (22F4

H

)

For callback

function

Accumulated count of callback receive procedure cancel

0 or more : Accumulated count

0

RW

Not allowed

Section

8.6.2

Chapter 3 of

User's

Manual

(Application)

8949 to 8954

(22F5

H

to 22FA

H

)

Use prohibited

System area

8955 (22FB

H

)

Accumulated count of unlock process normal completion

0 or more: Accumulated count of normal completion

8956(22FC

H

)

For the remote

password

function

Accumulated count of unlock process abnormal completion

processing

0 or more: Accumulated count of abnormal completion

0

RW

Not allowed

Section

5.1.5

Section

8.6.2

Chapter 3 of

User's

Manual

(Application)

8957 to 8958

(22FD

H

to

22FE

H

)

Use prohibited

System area

8959(22FF

H

)

For the remote

password

function

Accumulated count of lock process based on circuit disconnection

0 or more: Accumulated count of lock process based on circuit

disconnection

0

RW

Not allowed

Section

5.1.5

Section

8.6.2

Chapter 3 of

User's

Manual

(Application)

9216(2400

H

)

Use prohibited

System area

9217(2401

H

)

For flash ROM

write count

housing

Flash ROM write count

0 to 1000: Write count

0

R

Not allowed

9218 to 9427

(2402

H

to 25FF

H

)

Use prohibited

System area

9728 to 16383

(2600

H

to 3FFF

H

)

For user (

1)

User free area 2 (6656 words)

(Transmission/receiving data monitoring function default buffer)

Usage is determined by the user.

0

RW

Not allowed

1 Only QJ71C24N (-R2/R4) is usable. (System area when using QJ71C24 (-R2)

2 The following tables show the areas of block monitoring devices No. 1 to 10 (CH1

side: 8272 to 8361 (2050

H

to 20A9

H

), CH2 side: 8528 to 8617 (2150

H

to 21A9

H

)),

which are assigned for designating the PLC CPU monitoring function.