Appendix 1 Functional Improvements of the Q Series C24

The Q series C24 of function version B has several functions that have been added or
changed from the conventional product (function version A).
This chapter explains a comparison of the functions of Q series C24/GX Configurator-
SC accompanied by the change/addition of functions, and explains how to utilize
programs created for function version A as well as how to incorporate function version
B modules into the existing system.

Appendix 1.1 Comparison of the Functions of Q Series C24/GX Configurator-SC

(1) Comparison of the functions of Q series C24

The following table shows the functions of Q series C24.

Q series C24

(function version)

QJ71C24N

(-R2/R4)

QJ71C24

(-R2)

Function

B

B

A

Communication using the MC protocol

Communication with QnA compatible 2C/3C/4C frame

Communication with ASCII code

Communication with A compatible 1C frame

Formats 1 to 4

exist for each.

Communication with binary code

Communication with QnA compatible 4C frame

Format 5

Batch read/write in bit/word units

Monitoring of device memory

Batch read/write of multiple blocks

Read/write by extension designation

Read/write of device memory

Accessing other stations via network system

Reading/writing from/to the buffer memory of the Q series C24

Reading/writing from/to the buffer memory of intelligent function modules

Reading/writing from/to sequence program files

Monitoring the PLC CPUs (PLC CPU monitoring function)

Transmission of the monitoring information using the modem function.

Status control of the PLC CPUs (remote RUN/STOP, etc.)

Turning on/off input signals of the Q series C24 from an external device (global function)

Data transmission from a PLC CPU to an external device (on-demand function)

Communication using non-procedure protocol

Data transmission/reception in any format

Data transmission/reception using user frames

Data reception using format-0 (

2

)

Data reception using format-1

Data reception by interrupt programs

Monitoring the PLC CPUs (PLC CPU monitoring function)

Transmission of the monitoring information using the modem function.

ASCII data transmission/reception by ASCII-BIN conversion

Data transmission/reception by specifying transparent code

Specification of Receive transparent code

Specification of Transmission transparent 1st (

3

)

Multiple specification of Transmission transparent 2nd to 10th

Reception data clear by dedicated instruction (CSET instruction)