Clock Generator

6-4

The relationship between the input frequency (fosci) and the SYSCLK, MCLK, and IOCLK multiples and frequencies

is shown in Table 6-4-2, and the relationship between the input frequency (fosci) and the SYSCLK, MCLK, and
IOCLK multiples and frequencies when reset is released is shown in Table 6-4-3.

Table 6-4-2

Relationship between the Oscillation Mode and the SYSCLK, MCLK,

and IOCLK Frequencies

Input frequency

Oscillation mode Clock control register setting

SYSCLK

MCLK

IOCLK

fosci (MHz)

CKSEL

PLL

Register symbol: CKCTR Multiple

Frequency

Multiple

Frequency

Multiple

Frequency

Address: x’32004000

fsys (MHz)

fc (MHz)

fio (MHz)

8

fosci

15

MCK [1:0]= 10

1

8

fsys

15

4

32

fc

60*

1

8

fio

15

8

fosci

18

H

Used

MCK [1:0] = 01

1

8

fsys

18

2

16

fc

36

1/2

4

fio

9

MCK [1:0] = 00

1

8

fc

18

1/4

2

fio

4.5

8

fosci

20

L

Not used

Not used

1/2

4

fsys

10

1/2

4

fc

10

1/8

1

fio

2.5

*: In the case of the MN1030F01K, the maximum frequency for MCLK is 40 MHz.

Table 6-4-3

Relationship between the Input Frequency and the SYSCLK, MCLK,

and IOCLK Frequencies When Reset Is Released

Oscillation mode

Clock control register setting

SYSCLK

MCLK

IOCLK

CKSEL

PLL

Register symbol: CKCTR

Multiple

Multiple

Multiple

Address: x’32004000

H

Used

MCK [1:0] = 00

1

1

1/4

L

Not used

Not used

1/2

1/2

1/8

Note: When changing the input frequency during operation, be certain to enter the reset mode and set the CKSEL

pin to the prescribed value during reset mode.

The input frequency ranges shown here are preliminary. When using this LSI, contact our sales office for
the product specifications.