4 description of operation – Panasonic MN103001G/F01K User Manual

Page 312

Advertising
background image

Serial Interface

13-10

13.2.4

Description of Operation

<Clock synchronous mode>

Clock synchronous mode connection

Two different connection methods are possible, one for unidirectional transfer, and the other for bi-directional

transfer.
When SBT pin is an output only during transmission (SC0TOE = "0"), it is necessary to pull up SBT pin. In

addition, when using SBO pin as a data input/output (SC0MD1 and 0 = "11"), it is necessary to pull up SBO pin.
Connect a pull-up resistor externally.

When using SBO pin as a data output and SBI pin as a data input (SC0MD1 and 0 = "01"), the SBO pin is always
an output and the SBI pin is always an input.

When using SBO pin as a data input/output (SC0MD1 and 0 = "11"), the SBO pin is an output only during
transmission, and is normally an input.

When SC0TOE is "0", the SBT pin is an output only during transmission with the internal clock, and is normally an
input. Furthermore, when SC0TOE is "1", the SBT pin is always an output when the internal clock is selected.

Fig. 13-2-2 Connections

SBO

SBI

SBT

Transmission

SBO

SBI

SBT

Reception

SBO

SBI

SBT

Transmission/

reception

SBO

SBI

SBT

Transmission/

reception

Unidirectional transfer

Bi-directional transfer (SC0MD1 and 0 = “01”)

SBO

SBI

SBO

SBI

Bi-directional transfer (SC0MD1 and 0 = “11”)

SBT

SBT

Transmission/

reception

Transmission/

reception