Bus Controller (BC)

8-21

When using handshaking mode (Memory control register 3B

B3WM = 1)

Bit No.

Bit name

Description

Setting conditions

1

WM

Block 3 wait mode

1: Handshaking mode

2

BM

Block 3 bus mode

0: Synchronous mode (SYSCLK synchronization)

4

BW

Block 3 bus width

0:

8 bits

1:

16 bits

7 to 6

ASA1 to 0

AS assert timing

00:

0MCLK

11:

3MCLK

10 to 8

ASN2 to 0

AS negate timing

000:

prohibited

Set so that:

001:

1MCLK

ASN

ASA

111:

7MCLK

15 to 11

WEN4 to 0

WE negate timing

00000:

0MCLK

11111:

31MCLK

~

~

~

~

~

~

Note: Handshaking mode can only be set when (MCLK frequency/SYSCLK frequency) = 4.

If (MCLK frequency/SYSCLK frequency) = 1 or 2, set B3WM = 0 in MEMCTR3B.

After the reset is released, block 3 is set as follows:

Address output end timing

3MCLK

RE negate timing

29MCLK

WE negate timing

29MCLK

RE/WE assert timing

3MCLK

Bus cycle start timing

0MCLK

Bus cycle end timing

31MCLK

AS assert timing

1MCLK

AS negate timing

3MCLK

The bus width is 16 bits, and synchronous fixed wait mode is set.