16-bit Timers

11-13

Timer 10 compare/capture A mode register

Register symbol: TM10MDA

Address:

x'340010B0

Purpose:

This register controls the operation of the timer 10 compare/capture A register.

This register also sets the waveform that is output to the TM10IOA pin.

Bit No.

7

6

5

4

3

2

1

0

Bit

TM10 TM10 TM10 TM10

TM10 TM10 TM10

name

AM1 AM0 AEG ACE

AO2 AO1 AO0

Reset

0

0

0

0

0

0

0

0

Access

R/W

R/W

R/W

R/W

R

R/W

R/W

R/W

Bit No.

Bit name

Description

0

TM10AO0

Timer 10A output waveform selection flag (LSB)

1

TM10AO1

Timer 10A output waveform selection flag

2

TM10AO2

Timer 10A output waveform selection flag (MSB)
These bits select the waveform that is output to the TM10IOA pin.

000: Set when TMnBC matches TMnCA, reset when TMnBC matches TMnCB.
001: Set when TMnBC matches TMnCA, reset when TMnBC overflows.

010: Set when TMnBC matches TMnCA, reset only when the timer is initialized.
011: Reset when TMnBC matches TMnCA.

100: Toggled output (Output is inverted when TMnBC matches TMnCA.)
101, 110, 111: Setting prohibited.

3

"0" is returned when this bit is read.

4

TM10ACE

Timer 10 capture A operation enable flag

Enables/disables capture operation for TM10CA.

0: Disables capture operation. (Pin input is ignored.)

1: Enables capture operation.

5

TM10AEG

Timer 10 A pin polarity selection flag

Selects the valid edge for the input on the TM10IOA pin, and the output polarity.

0: Rising edge valid

Positive polarity output (Reset: “L” level; set: “H” level)

1: Falling edge valid

Negative polarity output (Reset: “H” level; set: “L” level)

6

TM10AM0

Timer 10 compare/capture A operating mode setting flag (LSB)

7

TM10AM1

Timer 10 compare/capture A operating mode setting flag (MSB)
These bits set the TM10CA operating mode.

00: Compare register (single-buffer)
01: Compare register (double-buffer)

10: Capture register (single-edge operation)
11: Capture register (dual-edge operation)

When dual-edge capture is set, the setting of TM10AEG is ignored.