Panasonic MN103001G/F01K User Manual

Page 180

Advertising
background image

Bus Controller (BC)

8-66

8.14.3

Software Page Mode

Software page mode is a mode that forcibly initiates page mode by setting the control register.

Operation within software page mode is as described below. Refer to Fig. 8-14-6.
•

When the mode is initiated, the contents of PRAR are output as the row address.

•

While the mode is in effect, RASn for the block corresponding to the memory control register that initiated the
mode is maintained in the asserted state.

•

After the mode is initiated, external accesses are all processed

as column address accesses

. In this case,

the ASC and CAS parameters of the block in question are guaranteed. In addition, the RE/WE signal has the

same waveform as in a normal DRAM access.

•

The CAS precharge interval depends on the timing of the external access. Note that the shortest CAS precharge

interval is ASC + 3 for a read, or ASC + 1 for a write. As an example, Fig. 8-14-6 illustrates the case where the
CAS precharge interval is at its shortest.

•

(CAO + 1) MCLK pulses are guaranteed for the row address output interval. (“CAO” is a parameter.)

•

The parameter ASR for the block in question is guaranteed for the assertion of RASn.

The procedure for executing this mode is described below:

■

Preparation for mode initiation

(1) Set the row address in the row address register PRAR.

Set a row address that has already been shifted according to the DRAM size.

(2) Set DRAMCTR.

Be certain to set the PAGE bit to “1” and the DRAME bit to “1”.

■

Mode initiation

Once the PE bit of the memory control register for the block in question (block 1 or 2) is set to “1”, software

page mode access begins after the register writing operation has been completed.

■

Mode termination

Once the PE bit of the memory control register for the block in question (block 1 or 2) is set to “0”, software
page mode is terminated after the register writing operation has been completed.

Note: When performing ICE trace/emulation in software page mode, set the CAS parameter to “5” or higher.

Advertising