8.14.3

Software Page Mode

Software page mode is a mode that forcibly initiates page mode by setting the control register.

Operation within software page mode is as described below. Refer to Fig. 8-14-6.

When the mode is initiated, the contents of PRAR are output as the row address.

While the mode is in effect, RASn for the block corresponding to the memory control register that initiated the
mode is maintained in the asserted state.

After the mode is initiated, external accesses are all processed

as column address accesses

. In this case,

the ASC and CAS parameters of the block in question are guaranteed. In addition, the RE/WE signal has the

same waveform as in a normal DRAM access.

The CAS precharge interval depends on the timing of the external access. Note that the shortest CAS precharge

interval is ASC + 3 for a read, or ASC + 1 for a write. As an example, Fig. 8-14-6 illustrates the case where the
CAS precharge interval is at its shortest.

(CAO + 1) MCLK pulses are guaranteed for the row address output interval. (“CAO” is a parameter.)

The parameter ASR for the block in question is guaranteed for the assertion of RASn.

The procedure for executing this mode is described below:

Preparation for mode initiation

(1) Set the row address in the row address register PRAR.

Set a row address that has already been shifted according to the DRAM size.

(2) Set DRAMCTR.

Be certain to set the PAGE bit to “1” and the DRAME bit to “1”.

Mode initiation

Once the PE bit of the memory control register for the block in question (block 1 or 2) is set to “1”, software

page mode access begins after the register writing operation has been completed.

Mode termination

Once the PE bit of the memory control register for the block in question (block 1 or 2) is set to “0”, software
page mode is terminated after the register writing operation has been completed.

Note: When performing ICE trace/emulation in software page mode, set the CAS parameter to “5” or higher.