Panasonic MN103001G/F01K User Manual

Page 315

Advertising
background image

Serial Interface

13-13

When a reception error is generated

Transfer in clock synchronous mode with 8-bit data length, parity on.

Fig. 13-2-7 Timing Chart (5)

When "reception end" is set as the reception interrupt source, an interrupt request is generated when reception ends,

regardless of whether or not an error occurred.
When "reception end with error" is set as the reception interrupt source, an interrupt request is generated when

reception ends with an error having occurred. (An interrupt request is not generated at the moment that the error
occurred.)

An overrun error is generated when reception of the next data is completed before previously received data is read
from the SC0RXB . In this event, the previously received data is lost. The overrun error indicator flag (SC0OEF)

is updated at the moment the final data bit is received.
A parity error is generated when 0-fixed parity is set and a "1" is received, when 1-fixed parity is set and a "0" is

received, when even parity is set and an odd number of ones is received, or when odd parity is set and an even
number of ones is received. The parity error indicator flag (SC0PEF) is updated at the moment the parity bit is

received.

bp1

bp2

bp3

bp4

bp5

bp6

bp0

SBI pin

SBT pin

SC0OEF flag

SC0RXF flag

SC0RBF flag

Interrupt request

bp7

SC0PEF flag

“H”

PTY

Advertising