Rainbow Electronics MG260 User Manual

Page 145

Advertising
background image

FLYFOT-MG260-MODULE

Page: 145 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.

1 : 8 Data 2 Stop (not supported)

<parity>parameter is ignored.

2 : 8 Data 1 Parity 1 Stop (not supported)

if no<parity> provided, 3 is used by default as <parity>value.

3 : 8 Data 1 Stop (supported)

<parity>parameter is ignored.

4 : 7 Data 2 Stop (not supported)

<parity>parameter is ignored.

5 : 7 Data 1 Parity 1 Stop (not supported)

if no<parity> provided, 3 is used by default as <parity>value.

6 : 7 Data 1 Stop (not supported)

<parity>parameter is ignored.

<parity>

0 : Odd (not supported)
1 : Even (not supported)
2 : Mark (not supported)
3 : Space (not supported)
4 : None (supported)

Notes :

z

Setting a character framing different from 8N1 will disable autobauding if it was activated. Setting
it back to 8N1 will not re-enable autobaud.

z

Setting the framing to 8N1 will let the autobauding enabled, if it was already enabled (implying
framing was already 8N1).

15.3 DTE-DCE local flow control +IFC

Description :

This command is used to control the operation of local flow control between the DTE and DCE.

Syntax :

Command syntax : AT+IFC=<DCE_by_DTE>,<DTE_by_DCE>
Command

Possible responses

AT+IFC?
Note :

+IFC: 2,2
OK
Note : Current values

AT+IFC=?
Note :

+IFC: (0,2),(0,2)
OK