Note : the embedded application is activated so the
objects flash are not erased.

AT+WOPEN = 4

+CME ERROR: 532

Note : the embedded application is

activated so it cannot be erased

Command

Possible responses

AT+WOPEN=0

OK

Note : Stop the embedded application.

+WIND: 3

Note : Product reset in order to stop the

embedded

application.

AT+WOPEN=3

OK

Note : The objects flash are erased

AT+WOPEN=4

OK

Note : the embedded application is

erased

AT+WOPEN?

+CME ERROR: 3

Note : The Open AT feature is disabled.

Defined values :

<Mode>

0 : Stop the Open-AT embedded application.

If the product was running, it resets.

1 : Start the Open-AT embedded application.

If the product was stopped, it resets.

2 : Get the Open AT library versions.
3 : Erase the objects flash of the Open-AT embedded application.
4 : Erase the Open-AT embedded application.

Note : Mode = 3 and 4 are only available if Open-AT embedded application is
stopped (AT+WOPEN=0).

<IntVersion>
Ascii string giving the internal Open AT library version.

<ExtVersion>
Ascii string giving the external Open AT library version.