FLYFOT-MG260-MODULE

Page: 27 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.

NOTE 1: The MT internally executes all commands necessary for selecting the desired file, before
performing the actual command.
<fileid> : integer type
This is the identifier of a elementary datafile on SIM. Mandatory for every command except STATUS.
NOTE 2: The range of valid file identifiers depends on the actual SIM and is defined in GSM 11.11
(or 3GPP TS 51.011). Optional files may not be present at all. This value must be in the range [0 .
65535] else a CME_ERROR=3 is returned.
<P1>, <P2>, <P3> : integer type
Parameters passed on by the MT to the SIM. These parameters are mandatory for every command,
except GET RESPONSE and STATUS. The values are described in GSM 11.11 (or 3GPP TS 51.011).
<data> : hexadecimal type
information which shall be written to the SIM (hexadecimal character format; refer +CSCS).
<sw1>, <sw2> : integer type
Information from the SIM about the execution of the actual command.
These parameters are delivered to the TE in both cases, on successful or failed execution of the
command.
<response> : hexadecimal type
response of a successful completion of the command previously issued (hexadecimal character format;
refer +CSCS). STATUS and GET RESPONSE return data, which gives information about the current
elementary datafield. This information includes the type of file and its size (refer GSM 11.11 (or 3GPP
TS 51.011)). After READ BINARY or READ RECORD command the requested data will be
returned.
<error>: integer type
3 Wrong format or parameters of the command
13 SIM no response

Advertising