Rainbow Electronics MG260 User Manual

Page 22

Advertising
background image

FLYFOT-MG260-MODULE

Page: 22 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.

AT+CCLK=”00/06/09,17:33:00+32”
Note : set date to June 9

th

, 2000, and time to

5:33pm, GMT +8

OK
Note : Date/Time stored

AT+CCLK=”00/13/13,12:00:00-16”
Note : Incorrect month entered

+CME ERROR 3

AT+CCLK?
Note : Get current date and time

+CCLK: “00/06/09,17:34:00+16”
OK
Note : current date is June 9

th

, 2000 current time

is 5:34:00 pm, GMT +4

AT+ CCLK =?
AT+ CCLK

+CME ERROR 3
Note: not support

Defined values :

<date and time string>
String format for date/time is: “yy/MM/dd,hh:mm:ss

±

zz”.

Valid years are 00 (for 2000) to 98 (for 2098).
Default date/time is “00/01/01,00:00:00+00” (January 1

st

, 2000 / midnight).

4.17 Alarm Management +CALA

Description :

This command is used to set alarms date/time in the ME. The maximum
number of alarms is 1.

Syntax :

Command syntax : AT+CALA=<date

and

time

string>

(set

alarm)

AT+CALA=” ” (delete alarm)

Command

Possible responses

AT+CALA=”00/06/09,07:30”
Note : set an alarm for June 9

th

, 2000 at 7:30 am

OK
Note : Alarm stored

AT+CALA=”99/03/05,13:00:00”
Note : set an alarm for March 5

th

, 1999 at 1:00 pm

+CME ERROR 3
Note : Invalid alarm (date/time expired)

AT+CALA?
Note : list all alarms

+CALA: “00/06/08,15:25:00”

CALA interruption

+CALA: “00/06/08,15:25:00”
Note : an alarm occurs

AT+CALA=””
Note : delete this alarm.

OK
Note : Alarm is deleted

AT+CALA?
Note : list all alarms

+CALA: “00/06/09,07:30:00”
Note : Only one alarm

AT+CALA = ?

OK

AT+CALA

+CME ERROR 3
Note: not support