4: Last item read (usable only if a read operation has been performed on the current phonebook since the
end of initialization)
5: Last item written (usable only if a write operation has been performed on the current phonebook since
the end of initialization)

8.7 Subscriber number +CNUM

Description:

This command returns the subscriber MSISDN(s).
If the subscriber has different MSISDNs for different services, each MSISDN is returned in a separate line.

Syntax:

Command syntax: AT+CNUM
Response syntax: +CNUM : <alpha1>, <number1>, <type1>

<CR><LF> +CNUM : <alpha2>, <number2>, <type2> ….

Command

Possible responses

AT+CNUM=?
Note : Test command

OK
Note : No parameter but this command is valid

AT+CNUM?
AT+CNUM=1

+CME ERROR: 3
Note: The product can not support this
command

AT+CNUM
Note : Get MSISDNs

+CNUM :“Phone”,“0612345678”,129
Note : MSISDNs

Defined values :

<alphax> optional alphanumeric string associated with <numberx>
<numberx> string type phone number with format as specified by <typex>
<typex> type of address byte in integer format

8.8 FLYFOT Phonebook Character Set +WPCS

Description :

This specific command informs the ME which character set is used by the TE for the phonebooks. The ME
can convert each character of entered or displayed strings. This is used to read or write phonebook entries.
See also +CSCS for the short messages character sets.

Syntax :

Command syntax : AT+WPCS=<Character Set>