Syntax :

Command syntax : AT+TMEL=<type>,< volume>
Command

Possible responses

AT+TMEL=2,3
Note: Set the alert type and volume

OK

AT+TMEL =?
Note: Get possible value

+TMEL: (0-15),(1-3)
OK

AT+TMEL =10,4
Note: Set invalid value

+CME ERROR: 3
Note: The product can not support this command

AT+ TMEL?
AT+ TMEL

+CME ERROR: 3
Note: The product can not support this command

Defined values :

<type> The value range is 0-15
0: none alert tone
(1-15): different alert tone

<volume> The value range is 1-3
1: The volume is lowest
2: The volume is middle
3: The volume is topmost



4.22 Control Flash LED Command +TFLED

Description

This command with six parameters is used to control the flash led sparking.

Syntax

AT+TFLED=[Operation],<light time in idle>,<dark time in idle>,<light in calling>,<dark in
calling>,<mode:>
Command

Possible responses

AT+ TFLED =?
Note: Set the alert type and volume

+TFLED:
(0-1),(0-65535),(0-65535),(0-65535),(0-65535),(0-1)
OK

AT+ TFLED =1,10,10,10,10 ,1
Note: Get possible value

OK

AT+ TFLED =10,4
Note: Set invalid value

+CME ERROR: 3
Note: The product can not support this command

AT+ TFLED?

+TFLED: 1,10,10,10,10,1

AT+ TFLED

+CME ERROR: 3
Note: The product can not support this command

Advertising