Rainbow Electronics MG260 User Manual

Page 214

Advertising
background image

FLYFOT-MG260-MODULE

Page: 214 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.

Defined values

<CmdType>

0 : Set active line
1 : Get active line

<LineId>:
Only used for <CmdType>= 0
1 : Line 1
2 : Line 2

18.41 FLYFOT Open AT control command +WOPEN

Description

This specific command allows to start, stop, delete and get information about the current Open AT
embedded application.
Note :This command is only available if the Open AT feature is enabled (cf +WCFM command).

Syntax

Command syntax AT+WOPEN=<Mode>
Response syntax +WOPEN: <Mode>[,<IntVersion>[<ExtVersion>]]

Command

Possible responses

AT+WOPEN=?

+WOPEN: (0-4)

OK

AT+WOPEN?

+WOPEN: 0

OK

AT+WOPEN=2

+WOPEN: 2, “AT v2.00”, “AT v2.00”

Note : Get the Open-AT library

OK

versions.

Note : Open-AT v2.00 library version. An

embedded application has been

downloaded on this product.

AT+WOPEN=3

OK

Note : The objects flash are erased

AT+WOPEN=1

OK

Note : Start the embedded application.

+WIND: 3

Note : Product reset in order to start the

embedded

application.

AT+WOPEN = 3

+CME ERROR: 532

Advertising