5.10 Microphone Mute Control +CMUT

Description :

This command is used to mute the microphone input on the product (for the active microphone set
with the +SPEAKER command). This command is only allowed during a call. Syntax:
Command syntax : AT+CMUT=<mode>
Command

Possible responses

AT+CMUT=?

Note: Test command

+CMUT: (0,1)
OK
Note: Enable / disable mute

AT+CMUT?

Note: Ask for current value

+CMUT: 0
OK
Note: Current value is OFF

AT+CMUT=1
Note: Mute ON (call active)

OK
Note: Command valid

AT+CMUT?

Note: Ask for current value

+CMUT: 1
OK
Note: Mute is active (call active)

AT+CMUT=0
Note: Mute OFF (call not active)

+CME ERROR:3
Note: Command not valid

Defined values :

<mode>
0 : microphone mute off (default value).
1 : microphone mute on.

5.11 Speaker & Microphone selection +SPEAKER