AT+WLOC=?

+CME ERROR:3

Note : The feature “loca” is not activated

AT+WLOC?

+CME ERROR:3

Note : The feature “loca” is not activated

AT+WLOC=?

Note : The feature “loca” is activated

OK

AT+WLOC?

Note : The location is not in mode

+WLOC: 0,5,255

automatic, the period value is set to 5

seconds, the configuration value is set to

OK

255

AT+WLOC?

+WLOC: 1,10,20

Note : The location is in mode automatic,

the period value is set to 10 seconds, the

OK

configuration value is set to 20

Defined values :

<mode>

0 : Stop automatic shots
1 : One shot requested
2 : Automatic shots requested (every x seconds)
3 : Configuration of the wished information

for <mode> = 2 :

<time period> optional parameter –
Range : [5 - 255] – in seconds
it has to be a multiple of 5.
default value of time period : 5 seconds
The automatic mode for location is saved in EEPROM, so will be taken into
account after an Init (+WLOC:… will be displayed).

Fields of the response to AT+WLOC=1 or AT+WLOC=2 :

The format of these fields are as specified in 04.08 :

Parameter

Type

MCC-MNC

3 bytes

LAC

2 bytes

CI

2 bytes

Network measurement

16 bytes

BCCH channel list

Maximum 48 bytes (version V0)