Command

Possible responses

AT+CRC=0
Note : Extended reports disabled

OK
Note : Command valid

AT+CRC=1
Note : Extended reports enabled

OK
Note : Command valid

AT+CRC?

+CRC: 1
OK

AT+CRC=?

+CRC: (0,1)
OK

Defined values:

<mode>:
0: disable extended reports
1: enable extended reports

16.5 DTE-DCE local rate reporting +ILRR

Description :

This parameter controls whether the extended-format “+ILRR:<rate>” information text is transmitted from
the DCE to the DTE or not. The <rate> value reported represents the current (negotiated or renegotiated)
DTE-DCE speed rate.
If enabled, the intermediate result code is transmitted in an incoming or outgoing data call, after any data
compression report, and before any final result code (CONNECT).

Syntax :

Command syntax : AT+ILRR = <value>
Command

Possible responses

AT+ILRR=0
Note : Local port rate report disabled

OK
Note : Command valid

AT+ILRR=1
Note : Local port rate report enabled

OK
Note : Command valid

AT+ILRR?

+ILRR: 1
OK

AT+ILRR=?

+ILRR: (0,1)
OK

Defined values:

<value>:
0: disable local port rate report
1: enable local port rate report