+WIND: <event>,<phonebook>,<status>,…,<phonebook>,<status>
Or for event 11:
+WIND: <event>,[“<checksum of SM>”],[“<checksum of FD>”],[“<checksum
of ON>”],[“<checksum of SN>”] ,[“<checksum of EN>”],[“<checksum of LD>”]
Defined values :
<IndLevel>
0 : no unsolicited “+WIND: <IndNb>” will occur (default value)
1 (bit 0) :
Hardware SIM Insert / Remove indications (Rack open/close) or SIM presence after
software reset
2 (bit 1) :
Calling party alert indication
4 (bit 2) :
Product is ready to process AT commands (except phonebooks, AOC, SMS), but still
in emergency mode.
8 (bit 3) :
the product is ready to process all AT commands, at the end of init or after swapping
to ADN in case of FDN configuration
16 (bit 4) :
a new call identifier has been created (after an ATD command, +CCWA indication)
32 (bit 5) :
an active, held or waiting call has been released by network or other party
64 (bit 6) :
Network service available indication
128 (bit 7) :
Network lost indication
256 (bit 8) :
Audio ON indication
512 (bit 9) :
SIM Phonebooks reload status
1024 (bit 10) :
Sim phonebooks checksum indication
2048 (bit 11) :
Interruption indication (only if FTR_INT is activated)
Combination (addition of the values) is used to allow more than one indication
flow : 0
≤ IndLevel ≤ 4095
The response is OK if the values are in the previous range.