Note :
If no embedded application is loaded, the<ExtVersion>parameter does not appear.

18.42 FLYFOT Reset +WRST

Description

This specific command resets the module after the time specified by the <delay> parameter.

Syntax

Command syntax : AT+WRST =<Mode>,<Delay>
Response syntax : +WRST: <Mode>,<Delay>,<RemainTime>

Command

Possible responses

AT+WRST=?

OK

AT+WRST=0

OK

Note : Disable timer

AT+WRST=1,”001:03”

OK

Note : Enable timer and set delay at 1

hour 3 minutes

AT+WRST?

+WRST: 1,”001:03”,”001:01” OK

Note: Timer activated to reset after 1

hour and 3 minutes. At this point, 1 hour and 1
minute remain before next reset.

Defined values :

<val1> :
0 : timer reset is disabled
1 : timer reset is enabled

<Delay>: sets the time before reset
Range “000:01”- “168:59” (format hhh:mm)

<RemainTime> : time before next reset
Range “000:01”- “168:59” (format hhh:mm)

18.43 Set Standard Tone +WSST