Rainbow Electronics MG260 User Manual

Page 175

Advertising
background image

FLYFOT-MG260-MODULE

Page: 175 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.

<key> : Keyboard map is (5,5)

0

1

2

3

4

5

6

7

8

9

10 11

12

13

14

15 16

17

18

19

20 21

22

23

24

<press>

1: key press
0: key release

<indresp> : indicator order number (as specified for +CIND)

<value> : new value of the indicator

18.4 Indicator control +CIND

Description :

This command is used to set the values of ME indicators. If ME does not allow setting of indicators or ME
is not currently reachable, an error code is returned.

Syntax :

Command Syntax: AT+CIND=[<ind>[,<ind>[,…]]]
Response syntax : +CIND: <descr>[,<descr>[,…]]
Command

Possible responses

AT+CIND=[<ind>[,<ind>[,…]]]

+CME ERROR: <err>
Note : ME not reachable

AT+CIND=[<ind>[,<ind>[,…]]]

OK

AT+CIND?
Note: read ME indicators current values

+CIND: <descr>[,<descr>[,…]]
OK

AT+CIND=?
Note: read possible value for ME indicators


+CIND:
("battchg",(0-5)),("signal",(0-5)),("service",(0-
1)),("message",(0-1)),("call",(0-1)),("roam",(0
-1)),("smsfull",(0-1))
OK

Defined values :

<ind>:
0: indicator is OFF or in state which can be identified as “OFF” state
1: indicator is ON or in a state that is more substantial than “OFF” state

Advertising