Syntax :

Command syntax : AT+VIP=<n>
Command

Possible responses

AT+VIP?

+VIP: 1
OK

AT+VIP=2
Note : Syntax error

+CME ERROR: 3

AT+VIP=1
Note : Restore the factory settings from EEPROM

OK
Note : The command has been executed

AT+VIP=1
Note : Restore the factory settings from EEPROM
with the current Echo cancellation algo (different of
the default algo).

CME ERROR: 519
Note : Reset the product to accept the new algo.

AT+VIP=?
Note : List of supported <n>s

+VIP: (1)
OK

Defined values :

<n>
1 : Restore all voice parameters
Other values are not supported.

5.15 Ring Melody Playback +CRMP

Description

This command allows a melody to be played. All melodies are manufacturer
defined.
For incoming voice, data or fax calls, 10 manufacturer-defined melodies can be
played back (in a loop).

Note:
loop melodies (for voice/data/fax call) must be stopped by a +CRMP command
with the <index> field set to 0 (example: +CRMP=0,,,0).
When the <volume> parameter is given, this overwrites the <sound level>
value of the +CRSL command. If the <volume> parameter is not given, the
<sound level> value of +CRSL is used as default value.

Syntax :

Command syntax : AT+CRMP=<call type>[,<volume>,<type>,<index>]