<Value>
0:close power.
1:open power.
<Type>
“IND”: indication control mode
<Value>

b32 … b4 b3 b2 b1

CSQ
CBC
CREG

UNUSED

m : this value has 4 octets. If the bit is set, the value of indication unsolicited once changing.

Otherwise the value is not given until requested.

4.20 32kHz Power down Mode +W32K

Description :

This specific command allows the 32kHz power down mode to be enabled or disabled.
Note :

z

When power down mode is entered, the product uses a 32kHz internal clock during

inactivity stages (despite of its nominal internal clock).

z

When enabled, power down mode is active after 1 to 15 minutes. The mode is not stored

in EEPROM : the command has to be repeated after a reset.

Syntax :

Command syntax : AT+W32K=<mode>
Command

Possible responses

AT+W32K=1

OK

Note : Enable 32kHz power down mode

Note : 32kHz power down mode is

enabled

AT+W32K=0

OK

Note : Disable 32kHz power down mode

Note : 32kHz power down mode is

disabled

Defined values

<mode> :
0 : Disable 32kHz power down mode

1 : Enable 32kHz power down mode