16.3 Service reporting control +CR

Description :

This command enables a detailed type of service reporting in the case of incoming or outgoing data calls.
Before sending the CONNECT response to the application, the product will specify the type of data
connection that has been set up.
These report types are :

Syntax :

Command syntax : AT+CR=<mode>
Command

Possible responses

AT+CR=0
Note : Extended reports disabled

OK
Note : Command valid

AT+CR=1
Note : Extended reports enabled

OK
Note : Command valid

AT+CR?

+CR: 1
OK

AT+CR=?

+CR: (0,1)
OK

Defined values:

<mode>:
0: disable extended reports
1: enable extended reports

16.4 Cellular result codes +CRC

Description :

This command allows more detailed ring information for an incoming call (voice or data). Instead of the
string “RING”, an extended string is used to indicate which type of call is ringing (e.g. +CRING: VOICE).
These extended indications are:

+CRING: ASYNC

for asynchronous transparent

+CRING: REL ASYNC

for asynchronous non-transparent

+CRING: VOICE

for normal speech.

+CRING : FAX

for fax calls

Syntax :

Command syntax : AT+CRC=<mode>

Advertising