Rainbow Electronics MG260 User Manual

Page 167

Advertising
background image

FLYFOT-MG260-MODULE

Page: 167 / 246

This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.

1 set timer of sending data
<time>

time of sending data timer. unit of second

Reference

Note

17.12 AT+CIPSPRT

AT+CIPSEND Set prompt of ‘>’ when sending data

Test command

AT+

CIPSPRT

=?

Response

+CIPSPRT: (0-NOT PROMPT,1-PROMPT)

OK

Parameter

See set command

AT+CIPSPRT?

Response

<send_prompt>

OK

Parameter

See set command

AT+ CIPSPRT =
<send_prompt>

Response

OK,
ERROR

Parameter

< send_prompt >

0 no prompt after issuing AT+CIPSEND command

1 with “>” prompt after issuing AT+CIPSEND command

Reference

Note

17.13 AT+CIPCSGP

AT+CIPCSGP Set CSD or GPRS for wireless connection mode

Test command

AT+

CIPCSGP

=?

Response

+CIPCSGP: 0-CSD,DIAL NUMBER,USER

NAME,PASSWORD,RATE(0,3)

+CIPCSGP: 1-GPRS,APN,USER NAME,PASSWORD

OK

Parameter

See set command

Query command

AT+CIPCSGP?

Response

<mode>

OK

Advertising