Description

Item

Enter letters or full words into this field to limit the list of available
signals.

List Filter

Lists the signals available for data acquisition.

Available list

Lists the signals selected for data acquisition.

Included list

Enter the amount of time between points in sec, hr, min, or mSec.
Maximum: 1 second.

Time Between Points

Enter a rate between 1–1024 Hz.

Sample Rate

Define the total number of samples to be recorded. Maximum: 61,440

Total Samples

Maximum: 61,440

Post-trigger Samples

Define the amount of time the recorder runs after shutdown.
Maximum: 60 seconds

Total Duration

Post-trigger Duration

Maximum: 60 seconds

About the Shutdown Recorder

With the Shutdown Recorder, you can capture and analyze data surrounding an unexpected shutdown.
Shutdown data is stored in volatile processor memory.

If a station unloads due to an application crash, data is retrieved by reloading the station, provided the system
is in a proper state. The Shutdown Recorder will not record data in the event of a power loss or a digital
supervisor application crash.

Memory considerations

Your controller must have a minimum of 64 MB of physical memory to use the Shutdown Recorder. You can
purchase a PMC flash module for non-volatile storage of shutdown data.