Command Options Tab

About Taper and Ramp Times

The Command Options tab’s Taper Times and Ramp Times values set the transition times between run, hold,
and stop states.

Access

Tools menu > Channel Options > Channel Options window > Command Options tab

Note:

The initial default setting for all times is 2.0 seconds.

Transition sources

Transitions between run, hold, and stop states can be initiated from many sources, including:

The Station Manager window’s Program Stop, Program Hold, and Program Run buttons

User-defined actions

Model 494.05 Handset

The Remote Station Control (RSC) panel

BTW applications

MPT applications

Transition states

When using the Station Manager Program Stop, Program Hold, and Program Run buttons, the following
applies:

Clicking Program Run initiates the transition to the run state.

Clicking Program Stop initiates the transition to the stop state.

Clicking Program Hold initiates the transition to the hold state.

Clicking Program Run after Program Hold initiates the transition to the run state.

Note:

Requires Tuning access level (or higher) to edit any item.

Taper Time Settings

Taper Times specify the time it takes command waveforms to go from zero amplitude to peak amplitude or
from peak amplitude to zero amplitude. This sets the transition time, where tapers are used, between run,
hold, and stop states.