Station builder shortcuts – MTS Series 793 User Manual

Page 463

Advertising
background image

Example

Default value

Abbreviation

1

Option

Description

/I 1

Interlock last used by
configuration

/I

/Interlock

Interlock number

/R RSC-1

RSC detected

/R

/RSC

RSC name

2

/V default /V saved /V
no

Default view

/V

/View

Restore view

/U Tuning

Operator

/U

/User

User access level

/Pas Tuning

None

/Pas

/Password

Password

3

/Hw tsiis.hwi

None

/Hw

/hwi

.hwi file name

/Sy “810 mat test”

None

/Sy

/System

System name

/Cont “Control A”

None

/Cont

/Controller

Controller name (to
connect to)

/Import Aero1.txt

None

None

/Import

Import parameters file

/Launch BTW

None

None

/Launch

Launch application

/Launch Project1

None

None

/Project (Project
name)

Launch Project

None

None

/NoRestart

No Restart (saved
applications)

/H

? or /Help

Display the Station
Manager
command-line options

Command line example

Stmgr /St test.cfg /Par “param set 1” /I 1 /V saved /U tuning /Pas Tuning

Station Builder Shortcuts

For Station Builder, you can use a shortcut to automatically specify the following parameters:

Configuration file name

Controller name (to connect to)

.hwi file name

1

Option names can be abbreviated to anything that is unique.

2

Optional—not available on all systems.

3

The password parameter is case-sensitive.

MTS Series 793 Control Software 463

Command Line Shortcuts

Advertising