How to set up apc compensators – MTS Series 793 User Manual

Page 251

Advertising
background image

Warning:

Clicking Reset (or Reset All) in this tab with hydraulic pressure on can result in unexpected
actuator movement.

A moving actuator can injure anyone in its path.

Always clear the actuator area before clicking Reset.

How to Set Up APC Compensators

1. Select an access level of Tuning.

2. In the Station Setup window navigation pane, locate and select the Channels control mode that requires

compensation.

3.

In the Station Setup window, click

.

4. On the Compensators panel, click the APC tab.

Warning:

Changes in compensation values made with hydraulic pressure on can result in unexpected
actuator movement.

A moving actuator can injure anyone in its path.

Always clear the actuator area before changing compensation values.

5. In the APC tab, define APC values:

a) Set the Convergence Rate.

b) For Adaptation State, select Resume.

Warning:

Changes in function generator frequency made with APC selected and hydraulic pressure
on can result in unexpected actuator movement.

A moving actuator can injure anyone in its path.

Avoid changing frequency values while running APC. If you must change the frequency,
always clear the actuator area first.

6. To save the values, go to the Station Manager window’s File menu and select Save Parameters.