Message logs, About message logs – MTS Series 793 User Manual

Page 337

Advertising
background image

Warning:

Changes in Set Point and Span values made with hydraulic pressure on can result in unexpected
actuator movement.

A moving actuator can injure anyone in its path.

Always clear the actuator area before changing values.

1.

In the Station Manager window Station Controls panel toolbar, click

.

2. In the Setpoint and Span window:

a) If the Channel button is available, click it to choose an individual channel or a Master Command Group.

b) Set the Setpoint.

c) Set the Span.

If necessary, click the Setpoint or Span text to display a window where you can change the slider-bar
range. These settings can be saved in a parameter set.

Message Logs

About Message Logs

Logged events

Message Logs record station and test events as they occur, including:

File events

Resource mismatches

Hydraulic and station state changes

Detector activity

Over-temperature conditions

Full-scale changes

MTS Series 793 Control Software 337