MTS Series 793 User Manual

Page 70

Advertising
background image

•

“DUC” is the type of resource, which is in this instance is a digital universal conditioner.

•

“S4” is the slot number in which the resource is installed in the controller chassis.

•

“J3A” is the connector label associated with the resource.

Hardware Resource Syntax Models

Syntax*/Comment

Example

Hardware Type

Syntax: <model> <type> <slot n> - <connector n>

494.25 DUC S4-J3A

Mezzanine Card

This syntax is used for all of the mezzanine cards
available for MTS I/O carrier boards.

Syntax: connector label

Monitor 1 Monitor 2 Anlg
Out (Model 493.42 System
I/O Board only)

Models 493.42 and
494.41 System I/O
Board

Syntax: <model> <type n> <transition n> - <connector n>

493.72 DO T1-J4

Transition Board

Syntax: <name> <channel n> - <temperature controller
n or device n> - <type>

Temp Control 1-4-Input

Temperature Control

Signal type may be input or output.

Syntax: <name> <type> <channel n> - <device n>

Wago DI 1-1

Modbus Device

“Wago” refers to the name of the manufacturer of the
Modbus Device.

*Explanation of resource types:

2SVD = Two-Stage Servovalve

3SVD = Three-Stage Servovalve

DUC = Digital Universal Conditioner

DI = Digital Input

DO = Digital Output

A/D = Analog-to-Digital Converter

D/A = Digital-to-Analog Converter

Other Resource Syntax Models

Comment

Syntax

Resource Type

Used to create a “virtual channel.” A virtual channel’s
output is not defined by an equation or assigned to

<<Virtual Output>>

Virtual Output

hardware, but its output is used by a calculated output
resource that may be used to drive hardware such as a
servovalve.

Used to create a calculated analog input for control
feedback or data acquisition. Calculated input values are

<<Calculated Input>>

Calculated Input

70 MTS Series 793 Control Software