Drive tab, Calculation tab – MTS Series 793 User Manual

Page 383

Advertising
background image

Note:

The Fullscale Min/Max values on this tab are only editable at the Calibration and Configuration access
level.

Drive Tab

This tab configures the drive signals of a calculated output channel. This tab’s contents vary with the type of
hardware used.

Access

Display menu > Station Setup > Station Setup window > navigation pane > Calculations > Calculated Outputs
> Calculated Output n > Drive tab

Drive Tab

Description

Item

Displays the valve driver’s full minimum and maximum output values.

Fullscale Min/Max

Sets the polarity of the valve drive signal to Normal or Invert.

Polarity

Polarity cannot be changed with station pressure on.

Compensates for minor mechanical imbalances in the servovalve.

Valve Balance

Adjusts the amplitude of the dither signal, a small high frequency signal that
keeps the servovalve from sticking.

Dither Amplitude

Calculation Tab

This tab displays the expression used to produce the selected calculated output’s drive signal.

Access

Display menu > Station Setup > Station Setup window > navigation pane > Calculations >Calculated Outputs
> Calculated Output n > Calculation tab

Note:

Requires Tuning access level (or higher) to edit any item.

Calculation Tab

Description

Item

Specifies the selected output’s full-scale minimum and maximum values. The
result of this calculation gets clipped to these values.

Fullscale Min/Max

Displays the formula used to produce the output.

Expression

Use the Calculation Editor window to define the formula.

MTS Series 793 Control Software 383

Calculated Signals

Advertising