Peak det. summary tab, Test log tab – MTS Series 793 User Manual

Page 441

Advertising
background image

Description

Item

Specifies the lower (valley) reference value (reference type must be
user-specified).

Lower Reference

Peak Det. Summary Tab

Use the Peak Det. Summary tab to determine the current status of each sensor signal.

Peak Det. Summary Tab

Description

Item

Specifies the sensor feedback signal monitored by a limit detector.

Signal

Indicates when a signal peak is above its “peak reference” tolerance band or a
signal valley is below its “valley reference” tolerance band

Over

Indicates when a signal peak is below its “peak reference” tolerance band or a
signal valley is above its “valley reference” tolerance band.

Under

Test Log Tab

Use the Test Log tab to select the level and source of the messages that are logged to the Basic TestWare
test log. Automatic deletion of archived log files of a specified age can also be selected here.

Test Log Tab

Description

Item

Message Capture

Allows you to select the level of messages logged.

Minimum Severity

Allows you to select the source of your logged messages.

Source

Select This Application Only to log only Basic TestWare messages.

Select All Applications to log messages from both Basic TestWare and Station
Manager.

Allows you to automatically delete old archived log files.

Archive Auto Deletion

Click the Delete Older Than check box and select the age (days) of the archive
log file required for automatic deletion.

MTS Series 793 Control Software 441