MTS Series 793 User Manual

Page 269

Advertising
background image

ALC Tab Settings

Description

Item

Sets how quickly compensation values get applied to converge the
feedback and command signal amplitudes.

Ampl. Convergence

Min—Fixed at 0.

Amplitude MIN/MAX

Max—Sets the factor by which the compensated command’s amplitude
can exceed the original command’s amplitude.

Sets how quickly compensation values get applied to converge the
feedback and command signal frequencies.

Freq Convergence

Min—Sets the minimum factor by which the compensated command’s
frequency can exceed the original command’s frequency.

Frequency MIN/MAX

Max—Sets the maximum factor by which the compensated command’s
frequency can exceed the original command’s frequency.

Hold All—Continues to use current values but stops adapting new values.

Adaptive State

Resume All—Adapts and continuously updates compensation values.

Clears acquired compensation values and restarts the adaptation process.

Reset All

Clicking Reset All with compensation applied may produce a spike in the
feedback signal.

How to Set Up Arbitrary End-Level Compensators (ALC)

1. Select an access level of Tuning.

2. In the Station Setup window’s navigation pane, locate and select the Channels control mode to receive

ALC.

3.

In the Station Setup window, click

.

4. On the Compensators panel, click the ALC tab.

Warning:

Changes in compensation values made with hydraulic pressure on can result in unexpected
actuator movement.

A moving actuator can injure anyone in its path.

Always clear the actuator area before changing compensation values.

5. In the ALC tab, define ALC values:

a) Set the Ampl. Convergence.

MTS Series 793 Control Software 269

Station Setup