Description

Examples

Resource Type

You can use digital universal conditioner resources to create
inputs and control modes for Channels and inputs for
Auxiliary Inputs.

493.25 DUC S12-J-4

494.16 DUC S4-J1A

494.21 DUC S6-J2A

494.25 DUC S6-J3A

494.26 DUC S4-J2A

Analog inputs are typically connectors located on the chassis
rear panel. Analog input resources can be used to receive
commands from external controllers (±10 volts output).

494.45 A/D 1 S4-J4A

493.45 A/D 1 S7-J11

493.57 A/D 1 S7-J15

A/D Inputs

You can use analog input resources to create inputs and
control modes for Channels and inputs for Auxiliary Inputs.

Wago A/D 1-1

You can use digital input resources to create Digital Inputs
and to support the enable switch of Remote Setpoints.

493.72 DI T1-J3

Wago DI 1-1

Digital Inputs

You can use encoder and sonic transducer conditioner
resources to create inputs and control modes for Channels,
and inputs for Auxiliary Inputs and Remote Setpoints.

493.47 Encoder S12-J7

493.59-1 U2 Absolute 1
S7-J17

Encoder and
Sonic Transducer
Conditioners

Note:

Absolute type encoder and Temposonics (sonic)
transducer conditioners are not available for Remote
Setpoints.

493.59-1 U2 Incremental 1
S7-J11

493.59-1 U2 Temposonics
III 1 S7-J13

494.47 Encoder S6-J2A

494.47 Encoder Velocity
S6-J2A

You can use temperature control resources to create inputs
and control modes for Channels and inputs for Auxiliary
Inputs.

Temp Control 1-1 Input

Temperature
Control

Calculated inputs are values generated by user-defined
algebraic formulas.

<<Calculated Input>>

Calculated Inputs

You can use calculated inputs to create inputs and control
modes for Channels, inputs for Auxiliary Inputs, and Digital
Inputs, and the enable switch of Remote Setpoints.

Resource Syntax

The syntax of the resource names in the hardware input and output resource lists reveal useful information
about the resources.

For example, a Model 494.25 Digital Universal Conditioner (DUC) mezzanine card may be displayed in the
Hardware Input Resource lists as “494.25 DUC S4-J3A”.

In this case:

“494.25” is the MTS Model number of the associated physical resource.