4. In the Station Manager window’s Station Controls panel:

a) Click Reset to clear any interlocks.

b) As needed, click Reset/Override to override interlocks.

Each Reset/Override click adds 10 seconds of override time.

c) Apply station hydraulic power.

When possible, use low pressure. As soon as power is applied, the Manual Command window’s Manual
Cmd shows the actual actuator position.

5. In the Manual Command window, select the Enable Manual Command check box.

6. If you are using a handset, select the Exculsive Control check box.

7. Use the Manual Cmd slider bar to position the actuator.

Note:

If necessary, click the Manual Cmd text to display a window where you can change the slider-bar
range.

How to Use Manual Command with Channel Groups

1.

In the Station Manager window’s Station Controls panel toolbar, click

to open the Manual Command

window.

2. Click the Channel button to toggle to Group.

3. Select the desired channel group for park or ride positioning.

4. Set the Park/Ride position for all actuators in the group.

a) Select the Enable Manual Command check box to activate manual command.

b) Move the low value slider and/or the high value slider so that they meet to form a “group value” slider.

c) Set the group value slider to the required Park or Ride position for all actuators in the group.

Note:

If necessary, click the Manual Cmd text to display a window where you can change the slider-bar
range.

How to Apply an Auto Offset to an Input Signal

1. Select an access level of Operator or above.

2. On the Station Manager window, click Display > Station Setup.

322 MTS Series 793 Control Software