Rockwell Automation 5730 DriveLogix5730 Controller for PowerFlex 700S Drives with Phase II Control User Manual

Page 131

Advertising
background image

Communicating with Devices on an EtherNet/IP Link

6-27

Configuring the MSG Instruction that Identifies the Mail Relay Server

In this field:

Enter:

Service Type

Set Attribute Single

Instance

1

Class

32f

Attribute

5

Source Element

the STRING tag that contains the IP address or host name of the mail relay server
In this example, enter EmailConfig

Source Length

the number of characters in the IP address or host name of the mail server plus 4
In this example, enter 17 (13 characters in the IP address 10.88.128.111 + 4)

a

hw0898.tif

1.

On the Configuration tab of the Message Configuration, fill out the following fields:

ahw0899.ti

f

2.

On the Communication tab of the Message Configuration, set the Path (e.g. browse for the
Embedded EtherNet Port).
Click Apply.
Click OK.

Advertising
This manual is related to the following products: