A-8
DriveLogix5730 Controller Specifications
Battery Life
Battery duration after the LED turns on
The battery indicator (BAT) warns you when the battery is low. These
durations are the amounts of time the battery will retain controller memory
from the time the controller is powered down after the LED first turns on.
Time ON/OFF
at 25
°C (77°F)
at 40
°C (104°F)
at 60
°C (140°F)
Always OFF
14 months
12 months
9 months
ON 8 hours per day
5 days per week
18 months
15 months
12 months
ON 16 hours per day
5 days per week
26 months
22 months
16 months
Always ON
There is almost no drain on the battery when the controller is always ON.