Rockwell Automation 5730 DriveLogix5730 Controller for PowerFlex 700S Drives with Phase II Control User Manual

Page 34

Advertising
background image

2-10

Placing and Configuring the Drive

Table 2.E Mapping for User-Defined 2 Communication Format

For each of the communication formats, drive_module:O.LogicCommand
and drive_module:I.LogicStatus are provided as DINT data types. In
addition to these tags, the control bits for each are also available as Boolean
values with tag names that correspond to the control bits in the drive. This
gives you the option of programming the Logic Command and Status words
at the Boolean level or as an integer value.

Not all 32-bits within parameter 151 [Logic Command], are directly visible
in the PowerFlex 700S. To view all 32-bits, refer to parameter 152 [Applied
LogicCmd].

Controller Output Tag Element

Drive Parameter

Linked Parameter

LogicCommand

602 [FromDriveLogix00]

151 [Logic Command]

UserDefinedRealData[0]

603 [FromDriveLogix01]

User Defined

UserDefinedRealData[1]

604 [FromDriveLogix02]

User Defined

UserDefinedRealData[2]

605 [FromDriveLogix03]

User Defined

UserDefinedRealData[3]

606 [FromDriveLogix04]

User Defined

UserDefinedRealData[4]

607 [FromDriveLogix05]

User Defined

UserDefinedRealData[5]

608 [FromDriveLogix06]

User Defined

UserDefinedRealData[6]

609 [FromDriveLogix07]

User Defined

UserDefinedRealData[7]

610 [FromDriveLogix08]

User Defined

UserDefinedRealData[8]

611 [FromDriveLogix09]

User Defined

UserDefinedRealData[9]

612 [FromDriveLogix10]

User Defined

UserDefinedRealData[10]

613 [FromDriveLogix11]

User Defined

UserDefinedIntegerData[0]

614 [FromDriveLogix12]

User Defined

UserDefinedIntegerData[1]

615 [FromDriveLogix13]

User Defined

UserDefinedIntegerData[2]

616 [FromDriveLogix14]

User Defined

UserDefinedIntegerData[3]

617 [FromDriveLogix15]

User Defined

UserDefinedIntegerData[4]

618 [FromDriveLogix16]

User Defined

UserDefinedIntegerData[5]

619 [FromDriveLogix17]

User Defined

UserDefinedIntegerData[6]

620 [FromDriveLogix18]

User Defined

UserDefinedIntegerData[7]

621 [FromDriveLogix19]

User Defined

UserDefinedIntegerData[8]

622 [FromDriveLogix20]

User Defined

Controller Input Tag Element

Drive Parameter

Linked Parameter

LogicStatus

626 [To DriveLogix00]

155 [Logic Status]

UserDefinedRealData[0]

627 [To DriveLogix01]

User Defined

UserDefinedRealData[1]

628 [To DriveLogix02]

User Defined

UserDefinedRealData[2]

629 [To DriveLogix03]

User Defined

UserDefinedRealData[3]

630 [To DriveLogix04]

User Defined

UserDefinedRealData[4]

631 [To DriveLogix05]

User Defined

UserDefinedRealData[5]

632 [To DriveLogix06]

User Defined

UserDefinedRealData[6]

633 [To DriveLogix07]

User Defined

UserDefinedRealData[7]

634 [To DriveLogix08]

User Defined

UserDefinedRealData[8]

635 [To DriveLogix09]

User Defined

UserDefinedRealData[9]

636 [To DriveLogix10]

User Defined

UserDefinedIntegerData[0]

637 [To DriveLogix11]

User Defined

UserDefinedIntegerData[1]

638 [To DriveLogix12]

User Defined

UserDefinedIntegerData[2]

639 [To DriveLogix13]

User Defined

UserDefinedIntegerData[3]

640 [To DriveLogix14]

User Defined

UserDefinedIntegerData[4]

641 [To DriveLogix15]

User Defined

UserDefinedIntegerData[5]

642 [To DriveLogix16]

User Defined

UserDefinedIntegerData[6]

643 [To DriveLogix17]

User Defined

UserDefinedIntegerData[7]

644 [To DriveLogix18]

User Defined

UserDefinedIntegerData[8]

645 [To DriveLogix19]

User Defined

UserDefinedIntegerData[9]

646 [To DriveLogix20]

User Defined

Advertising
This manual is related to the following products: