Access Procedures

12.On the front of the controller, is the BATTERY LED off?

13.Download the controller’s memory and program from the computer with

RSLogix 5000 programming software.

14.Remove power from the drive and the DriveLogix5730 controller. Verify

that the voltage on the bus capacitors has discharged before performing
any work on the drive. Measure the DC bus voltage at the +DC & –DC
terminals of the Power Terminal Block. The voltage must be zero.

15.Disconnect from the communication port.

16.Re-install the cover(s).

17.Dispose the old battery according to state and local regulations.

If:

Then:

Yes

Go to the next step.

No

A. Check that the battery is correctly connected to the controller.
B. If the BATTERY LED remains on, install another 1769-BA battery.
C. If the BATTERY LED remains on after you complete Step B., contact your

Rockwell Automation representative or local distributor.

!

ATTENTION: Do not incinerate or dispose lithium batteries
in general trash collection. They may explode or rupture
violently. Follow state and local regulations for disposal of
these materials. You are legally responsible for hazards
created while your battery is being disposed.