Communicating with Devices on a Serial Link
5-7
Example 2: Workstation
Remotely Connected to a
DriveLogix Controller
In the following example, a workstation remotely connects to a DriveLogix
controller over s serial link. A modem is connected to the controller to
provide remote access.
If you use a modem to remotely connect the controller to one workstation,
use RSLogix 5000 programming software to configure the serial port of the
controller for the DF1 point-to-point (full-duplex) protocol, as in the
previous example. If the controller is part of a master/slave serial network,
configure the serial port of the controller for either the DF1 master or DF1
slave protocol (both half-duplex).
ahw0920.eps
modem
modem