Communicating with Devices on an EtherNet/IP Link

6-35

Total Connections Required by DriveLogix1

The following table calculates the connections used in this example.

Receiving a MSG Instruction

When other devices send messages to the DriveLogix5730 controller, the
path for the message must identify the controller. Configure a CIP-type
message in the originating device. Specify the path the DriveLogix5730
controller as:

Connection:

Amount:

connected, cached MSG from DriveLogix1 to DriveLogix2

1

produced tagA
produced from DriveLogix1 to DriveLogix2
other consumer (2 are configured)

1
1

consumed tagB

1

total connections used: 4

xxx.xxx.xxx.xxx,1,1

IP Address

virtual backplane

slot 1