Rockwell Automation 5730 DriveLogix5730 Controller for PowerFlex 700S Drives with Phase II Control User Manual

Page 89

Advertising
background image

Configuring DriveLogix Motion

4-19

Make the parameter settings shown in the table below:

Table 4.B Parameter Settings for DriveLogix Motion Configuration

8.Type the desired value.

ahw0829.ti

f

Parameter

Value

Description

13 [Spd Ref2 Multi]

1

Speed Ref 2 scale value

24 [Spd Trim 3 Scale]

0.003

Speed Trim 3 scale value

27 [Speed Ref A Sel]

2

Select Speed Ref 2 as the speed reference

146 [FW TaskTime Sel]

(1)

(1)

Changes to these parameters require a drive reset before the changes will take effect. The HIM will indicate
“Reset Req’d” on the status line.

0

Firmware Task Time Selection.

147 [FW Functions En]

16 = 1

Position Control enabled

151 [Logic Command]

Bit 0 = 1
Bit10 = 1
Bit13 = 1

Bit 0 bypasses the speed ramp in the drive
Bit 10 enables Inertia Comp
Bit 13 enables the position loop within the drive.

222 [Motor Fdbk Sel Pri]

0 - 6

Select the Motor Speed Feedback being used. This is also
the feedback for the Servo Axis in DriveLogix Motion Group

600 [Lgx Comm Format]

19

This selects the format of the commands coming from
DriveLogix

686 [Motn Config]

Bits 0 - 2 Bit 0 = Change the polarity of the feedback only feedback

axis
Bit 1 = Enable Software Overtravel Limits
Bit 2 = Enable Hardware Overtravel Limits

701 [FdbkAxis FdbkSel]

1 – 10

This selects the feedback channel used for the “Feedback
Only axis” in the Motion Group in DriveLogix.

Encoders, Optional Feedback, and SynchLink selections.
See User Manual for details.

740 [Position Control]

Bit 1 = 1
Bit 6 = 0
Bit 2 = 1
Bit 8 = 0

This sets the position regulator to work with the DriveLogix
configuration and enables the Integral part of the regulator

742 [Position Ref Sel]

0

This configures the drive position loop to receive position
commands from DriveLogix via the Interpolator

824 [Local I/O Status]

Bit 0 = 0
Bit 1 = 1

Eliminate erroneous physical axis faults

904 [SL Node Cnfg]

(1)

Bit 0 =1

This sets up the SynchLink as the time keeper. This is used
to synchronize the Drive and DriveLogix.

Advertising
This manual is related to the following products: