Communicating with Devices on a DeviceNet Link

ahw0950.ti

f

3.

Click on the adapter, then click on the single arrow pointing to the right.
This moves the adapter from Available Devices to the scanner’s scanlist.

Then click on the Edit I/O Parameters button

a

hw0952.tif

5.

Click on the Input tab.

Then click Apply and OK.

Download when prompted.

4.

Verify that the Input Size and Output Size are correct. The Output and Input sizes correspond to the total

number of output and input

bytes noted from the adapter’s summary page. In this example, the scanner transmits 6 bytes to the adapter

(output data) and

receives 28 bytes from the adapter (input data).

Click OK when finished with this screen.

a

hw0951.tif