Component Definition and Maintenance 6-71
7000 “B” Frame
7000-UM150I-EN-P – June 2013
AC/DC Power Supply (cont.)
Replacement procedure
1. Ensure 3-phase control power has been isolated and locked out.
2. Disconnect the terminals at the top of the unit.
3. Remove the two M6 bolts per Figure 6.53.
4. Extract the power supply complete with left-side mounting
bracket from the drive.
5. Remove the mounting bracket from the failed power supply
(four M4 screws). Retain the insulation sheet.
6. Attach mounting bracket to replacement power supply. Ensure
that the insulating sheet between the bracket and power supply is
installed.
7. Install new power supply in drive; install M6 bolts.
8. Re-connect terminals at the top of the unit.
9. Reapply control power and verify voltage levels.
Insulation Sheet
Power Supply
Mounting Bracket
M4 screw
Insulation Sheet
Power Supply
Mounting Bracket
Insulation Sheet
Power Supply
Mounting Bracket
M4 screw
Figure 6.53 – Replacement of AC/DC Power Supply